IPv6 Support
10.3 Firewall Support for IPv6
SCALANCE W1750D UI
106 Configuration Manual, 02/2018, C79000-G8976-C451-02
10.3
Firewall Support for IPv6
For a given client, a single ACL is used to firewall both IPv4 and IPv6 rules. A rule
any any
match any any any permit
in the access rule configuration will expand to two different ACL
entries:
any any any P6
any any any P4
Similarly, if any IPv6 specific rule is added. For example, if any DHCPv6 or FTPv6 rule is
added, the ACE would be expanded as follows:
any 2002::/64 17 0-65535 546-547 6
destined to network 2002::/64 DHCPv6 is denied
.
any 2001::10/128 6 0-65535 20-21 6
destined to host 2001::10 FTP is denied
.
For all ACLs the AP will have an implicit IPv4 and IPv6
allow all
acl rule