Wired Profiles
12.5 Link Aggregation Control Protocol
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
157
12.5.1
Enabling Port-Channel on a Switch
To enable port-channel on an S3500 Mobility Access Switch:
1. Create a switching profile by running the following commands:
(scalance)(config)# interface-profile switching-profile <profile-name>
(scalance)(Switch Profile <profile-name>)# switchport-mode {trunk}
(scalance)(Switch Profile <profile-name>)# exit
2. Create a port-channel and associate the switching profile by running the following
commands:
(scalance)(config)# interface port-channel <0-63>
(scalance)(config)# port-channel-members [<interface-list>|[add|delete]
(scalance)(config)# gigabitethernet <slot/module/port>]
(scalance)(config)# shutdown
(scalance)(config)# switching-profile <profile-name>
Verifying LACP Configuration on the AP
There is no configuration required on the AP for enabling LACP support. However, you can
view the status of LACP on APs by using the following command:
(scalance)# show lacp status
AP LACP Status
--------------
Link Status
LACP Rate
Num Ports
Actor Key
Partner Key
Partner MAC
-----------
---------
---------
---------
-----------
-----------
Up
slow
2
17
1
70:81:05:11:3e:80
Slave Interface Status
----------------------
Slave I/f Name Permanent MAC Addr Link Status Member of LAG Link Fail Count
-------------- ------------------ ----------- ------------- ---------------
eth0 6c:f3:7f:c6:76:6e Up Yes 0
eth1 6c:f3:7f:c6:76:6f Up Yes 0
Traffic Sent on Enet Ports
--------------------------
Radio Num
Enet 0 Tx Count
Enet 1 Tx Count
---------
---------------
---------------
0
0
0
1
0
0
non-wifi
2
17

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals