Intrusion Detection
27.3 Configuring Wireless Intrusion Protection and Detection Levels
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
443
27.3
Configuring Wireless Intrusion Protection and Detection Levels
WIP offers a wide selection of intrusion detection and protection features to protect the
network against wireless threats.
Like most other security-related features of the SCALANCE W network, the WIP can be
configured on the AP. You can configure the following options:
Infrastructure Detection Policies
Specifies the policy for detecting wireless attacks on
access points.
Client Detection Policies
Specifies the policy for detecting wireless attacks on clients.
Infrastructure Protection Policies
Specifies the policy for protecting access points from
wireless attacks.
Client Protection Policies
Specifies the policy for protecting clients from wireless
attacks.
Containment Methods
Prevents unauthorized stations from connecting to your
SCALANCE W network.
Each of these options contains several default levels that enable different sets of policies. An
administrator can customize, enable, or disable these options accordingly.
The detection levels can be configured using the
IDS
window. To view the IDS window, click
More > IDS
link on the SCALANCE W main window.
The following levels of detection can be configured in the WIP Detection page:
Off
Low
Medium
High
Figure 27-2 Wireless Intrusion Detection