AP-VPN Deployment Scenarios
35.2 Scenario 2 - IPsec: Single Datacenter with Multiple controllers for Redundancy
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
535
35.2
Scenario 2 - IPsec: Single Datacenter with Multiple controllers for
Redundancy
This scenario includes the following configuration elements:
A VRRP instance between the master/standby-master pair, which is configured as the
primary VPN IP address.
Tunneling of all traffic to datacenter.
Exception route to bypass tunneling of RADIUS and AirWave traffic, which are locally
reachable in the branch and the Internet, respectively.
All client DNS queries are tunneled to the controller.
Distributed, L3 and Centralized, L2 mode DHCP on all branches. L3 is used by the
employee network and L2 is used by the guest network with captive portal.
Wired and wireless users in L2 and L3 modes.
Access rules defined for wired and wireless networks.