AP Maintenance
31.2 Backing up and Restoring AP Configuration Data
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
473
31.2
Backing up and Restoring AP Configuration Data
You can back up the AP configuration data and restore the configuration when required.
Viewing Current Configuration
To view the current configuration on the AP:
In the UI, navigate to
Maintenance > Configuration > Current Configuration
.
In the CLI, enter the following command at the command prompt:
(scalance)# show running-config
Backing up Configuration Data
To back up the AP configuration data:
1. Navigate to the
Maintenance > Configuration
page.
2. Click
Backup Configuration
.
3. Click
Continue
to confirm the backup. The
instant.cfg
containing the AP configuration
data is saved in your local file system.
4. To view the configuration that is backed up by the AP, enter the following command at
the command prompt:
(scalance)# show backup-config
Restoring Configuration
To restore configuration:
1. Navigate to the
Maintenance > Configuration
page.
2. Click
Restore Configuration
.
3. Click
Browse
to browse your local system and select the configuration file.
4. Click
Restore Now
.
5. Click
Restore Configuration
to confirm restoration. The configuration is restored and the
AP reboots to load the new configuration.
(scalance)(config)# copy config tftp://x.x.x.x/confgi.cfg

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals