Uplink Configuration
26.5 Uplink Preferences and Switching
SCALANCE W1750D UI
438 Configuration Manual, 02/2018, C79000-G8976-C451-02
(scalance)(uplink)# end
(scalance)# commit apply
To enable uplink switching based on Internet availability:
(scalance)(config)# uplink
(scalance)(uplink)# failover-internet
(scalance)(uplink)# failover-internet-ip <ip>
(scalance)(uplink)# failover-internet-pkt-lost-cnt <count>
(scalance)(uplink)# failover-internet-pkt-send-freq <frequency>
(scalance)(uplink)# end
(scalance)# commit apply
26.5.5
Viewing Uplink Status and Configuration
To view the uplink status:
(scalance)# show uplink status
Uplink preemption :enable
Uplink preemption interval 600
Uplink enforce :none
Ethernet uplink eth0 :DHCP
Uplink Table
Type State Priority In Use
---- ----- -------- ------
eth0 UP 2 Yes
Wifi-sta INIT 1 No
3G/4G INIT 3 No
Internet failover :enable
Internet failover IP :192.2.0.1
Max allowed test packet loss :10
Secs between test packets 30
VPN failover timeout (secs) 180
Internet check timeout (secs) 10
ICMP pkt sent 1
ICMP pkt lost 1
Continuous pkt lost 1
VPN down time 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals