Mesh AP Configuration
28.2 Setting up SCALANCE W Mesh Network
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
453
28.2
Setting up SCALANCE W Mesh Network
Mesh functionality is disabled by default, because of which over- the-air provisioning of mesh
APs is not supported.
To provision APs as mesh APs:
1. Connect the APs to a wired switch.
2. Ensure that the VC key is synchronized and the country code is configured.
3. Ensure that a valid SSID is configured on the AP.
4. If the AP has a factory default SSID (SCALANCE W SSID), delete the SSID.
5. If an extended SSID (ESSID) is enabled on the VC, disable it and reboot the AP cluster.
6. Disconnect the APs that you want to deploy as mesh points from the switch, and place
the APs at a remote location. The APs come up without any wired uplink connection and
function as mesh points. The APs with valid uplink connections function as mesh portals.
Note
SCALANCE W does not support the
topology in which the APs are connected to the
downlink Ethernet port of a mesh point.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals