Wired Profiles
12.1 Configuring a Wired Profile
SCALANCE W1750D UI
148 Configuration Manual, 02/2018, C79000-G8976-C451-02
as Uplink port. For more information on assigning a wired network profile to a port, see
Assigning a Profile to Ethernet Ports (Page 155).
–
—Select the
check box to enable Spanning Tree
Protocol (STP) on the wired profile. STP ensures that there are no loops in any
bridged Ethernet network and operates on all downlink ports, regardless of forwarding
mode. STP will not operate on the uplink port and is supported only on APs with three
or more ports.
By default, Spanning Tree is disabled on wired profiles.
–
—Specify the time out interval within the range of 60–86,400
seconds for inactive wired clients.
The default interval is 1000 seconds.
5. Click
. The
tab details are displayed.
6. Configure VLAN for the wired profile. For more information, see Configuring VLAN for a
Wired Profile (Page 149).
To configure the settings for a wired profile:
(scalance)(config)# wired-port-profile <name>
(scalance)(wired ap profile <name>)# type {<employee>|<guest>}
(scalance)(wired ap profile <name>)# speed {10|100|1000|auto}
(scalance)(wired ap profile <name>)# duplex {half|full|auto}
(scalance)(wired ap profile <name>)# no shutdown
(scalance)(wired ap profile <name>)# poe
(scalance)(wired ap profile <name>)# uplink-enable
(scalance)(wired ap profile <name>)# content-filtering
(scalance)(wired ap profile <name>)# spanning-tree
(scalance)(wired ap profile <name>)# end
(scalance)# commit apply