Authentication and User Management
14.4 Configuring Authentication Servers
SCALANCE W1750D UI
Configuration Manual, 02/2018 , C79000-G8976-C451-02
217
Enabling Dynamic RADIUS Proxy
You can enable RADIUS server support using the SCALANCE W UI or the CLI.
In the SCALANCE W UI
To enable RADIUS server support:
1. In the SCALANCE W main window, click the
System
link. The
System
window is
displayed.
2. On the
General
tab of the
System
window, select the
RADIUS
check box for
Dynamic
Proxy
.
3. Click
OK
.
Note
When dynamic RADIUS proxy is enabled, the VC network uses the IP Address of the VC for
communication with external RADIUS servers. Ensure that the VC IP Address is set as a
NAS IP when configuring RADIUS server attributes with dynamic RADIUS proxy enabled.
For more information on configuring RADIUS server attributes, see
Configuring an External
Server for Authentication
(Page 209).
Note
In case of VPN deployments, the tunnel IP received when establishing a VPN connection is
used as the NAS IP. In such cases, the VC IP need not be configured
for the external
RADIUS servers.
In the CLI
To enable the dynamic RADIUS proxy feature:
(scalance)(config)# dynamic-radius-proxy
(scalance)(config)# end
(scalance)# commit apply
Configuring Dynamic RADIUS Proxy Parameters
You can configure DRP parameters for the authentication server by using the SCALANCE W
UI or the CLI.
In the SCALANCE W UI
To configure dynamic RADIUS proxy in the SCALANCE W UI:
1. Go to
Security
>
Authentication Servers
.
2. To create a new server, click
New
and configure the required RADIUS server parameters
as described in Table 33.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals