VPN Configuration
19.2 Configuring a Tunnel from an AP to a Mobility Controller
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
319
------------ ----------- --------------- ----------- ----------- --------------------
-
-------------- ---------------------
test_session 1.1.1.1 255.255.255.0 5 0
0 0
To view L2TPv3 global configuration:
(scalance)# show l2tpv3 global parameter
L2TPV3 Global configuration
---------------------------
Host Name
----------
scalance-C4:42:98
To view L2TPV3 session status:
(scalance)# show l2tpv3 session status
Session 1821009927 on tunnel 858508253:-
type: LAC Incoming Call, state: ESTABLISHED
created at: Jul 2 04:58:45 2013
administrative name: 'test_session' (primary)
created by admin: YES, peer session id: 12382
session profile name: test_session_primary
data sequencing required: OFF
use data sequence numbers: OFF
Peer configuration data:-
data sequencing required: OFF
framing types:
data rx packets: 16, rx bytes: 1560, rx errors: 0 rx cookie error 0
data tx packets: 6, tx bytes: 588, tx errors: 0
To view L2TPV3 tunnel status:
(scalance)# show l2tpv3 tunnel status
Tunnel 858508253, from 10.13.11.29 to 10.13.11.157:-
state: ESTABLISHED
created at: Jul 2 04:58:25 2013
administrative name: 'test_tunnel' (primary)
created by admin: YES, tunnel mode: LAC, persist: YES