Deep Packet Inspection and Application Visibility
22.6 Configuring Web Policy Enforcement Service
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
373
In the CLI
To control access based on web categories and security ratings:
(scalance)(config)# wlan access-rule <access_rule>
(scalance)(Access Rule "<access-rule>")# rule <dest> <mask> <match> webcategory
<webgrp>
{permit | deny}[<option1....option9>]
(scalance)(Access Rule "<access-rule>")# rule <dest> <mask> <match> webreputation
<webrep>
{permit | deny}[<option1....option9>]
(scalance)(Access Rule "<access-rule>")# end (scalance)# commit apply
Example
The following CLI example shows how to set access rules based on the web category and
the web reputation:
(scalance)(config)# wlan access-rule URLFilter
(scalance)(Access Rule "URLFilter")# rule any any match webcategory gambling deny
(scalance)(Access Rule "URLFilter")# rule any any match webcategory training-and-
tools permit
(scalance)(Access Rule "URLFilter")# rule any any match webreputation suspicious-
sites deny
(scalance)(Access Rule "URLFilter")# end
(scalance)# commit apply