24.2 Configuring an AP for RTLS Support
SCALANCE W1750D UI
396 Configuration Manual, 02/2018, C79000-G8976-C451-02
4. Specify the IP address and port to which the location reports must be sent.
5. Specify the shared secret key in the
Passphrase
text box.
6. In the
Update
text box, specify the frequency at which the VC can send updates to the
server. You can specify a value within the range of 5-3600 seconds.
The default value is
5 seconds.
7. Select the
Include unassociated stations
check box to send reports to the RTLS server
about the stations that are not associated to any AP.
8. Click
OK
.
To configure third-party RTLS such as Aeroscout:
1. Select the
Aeroscout
check box to send the RFID tag information to an AeroScout RTLS.
2. Specify the IP address and port number of the AeroScout server to which location reports
must be sent.
3. Select the
Include unassociated stations
check box to send reports on the stations that
are not associated to any AP to the Aeroscout RTLS server.
4. Click
OK
.
In the CLI
To configure AirWave RTLS:
(scalance)(config)# airwave-rtls <IP-address> <port> <passphrase> <seconds> include-
unassoc- sta
(scalance)(config)# end
(scalance)# commit apply
To configure Aeroscout RTLS:
(scalance)(config)# aeroscout-rtls <IP-address> <port> include-unassoc-sta
(scalance)(config)# end
(scalance)# commit apply

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1750D UI and is the answer not in the manual?

Siemens SCALANCE W1750D UI Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1750D UI
CategoryWireless Access Point
LanguageEnglish

Related product manuals