Services
24.6 Integrating an AP with Palo Alto Networks Firewall
SCALANCE W1750D UI
404 Configuration Manual, 02/2018, C79000-G8976-C451-02
Configuring an AP for PAN integration
In the SCALANCE W UI
To configure PAN firewall integration in an AP:
1. Click
More > Services
.
2. Click
Network Integration
. The PAN firewall configuration options are displayed.
Figure 24-8 Services Window: Network Integration Tab
3. Select the
Enable
check box to enable PAN firewall.
4. Provide the user credentials of the PAN firewall administrator in the
Username
and
Password
text boxes.
5. Enter the PAN firewall IP address.
6. Enter the port number within the range of 1–65,535. The default port is 443.