EasyManua.ls Logo

Siemens SCALANCE W1750D UI

Siemens SCALANCE W1750D UI
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Services
24.8 CALEA Integration and Lawful Intercept Compliance
SCALANCE W1750D UI
Configuration Manual, 02/2018, C79000-G8976-C451-02
415
(scalance)(SSID Profile"Calea-Test")# end
(scalance)(SSID Profile"Calea-Test")# commit apply
To verify the configuration:
(scalance)# show calea config
calea-ip :10.0.0.5 encapsulation-type :gre gre-type :25944
ip mtu : 150
To view the tunnel encapsulation statistics:
(scalance)# show calea statistics
Rt resolve fail : 0
Dst resolve fail: 0
Alloc failure : 0
Fragged packets : 0
Jumbo packets : 263
Total Tx fail : 0
Total Tx ok : 263