If you want to apply the configuration immediately and do not want to wait until next
configuration retrieval attempt, execute the following command:
(scalance)# managed-mode-sync-server
Example
To configure managed mode profile:
(scalance)(config)# managed-mode-profile
(scalance)(managed-mode-profile)# username <username>
(scalance)(managed-mode-profile)# password <password>
(scalance)(managed-mode-profile)# config-filename instant.cfg
(scalance)(managed-mode-profile)# download-method ftps
(scalance)(managed-mode-profile)# sync-time day 00 hour 03 min 30 window 02
(scalance)(managed-mode-profile)# retry-poll-period 10
(scalance)(managed-mode-profile)# end
(scalance)# commit apply