Monitoring Devices and Logs
32.2 Configuring a Syslog Server
SCALANCE W1750D UI
488 Configuration Manual, 02/2018, C79000-G8976-C451-02
In the CLI
To configure a syslog server:
(scalance)(config)# syslog-server <IP-address>
To configure syslog facility levels:
(scalance)(config)# syslog-level <logging-level>[ap-debug |network |security |system
|user | user-debug | wireless]
(scalance)(config)# end (scalance)# commit apply
To view syslog logging levels:
(scalance)# show syslog-level
Logging Level
-------------
Facility Level
-------- -----
ap-debug warn network warn security warn system warn user warn
user-debug warn wireless error