Do you have a question about the Steris Vision 1321 and is the answer not in the manual?
Category | Medical Equipment |
---|---|
Model | Vision 1321 |
Manufacturer | Steris |
Sterilization Temperature Range | 121°C to 134°C |
Sterilization Time | 4 minutes |
Power Requirements | 208-240 VAC, 50/60 Hz, Single Phase, 20A |
Door Type | Automatic |
Cycle Options | Gravity, Liquid |
Warnings and cautions for personal injury and equipment damage.
Checklist to ensure complete and correct installation of the equipment.
General description of how a typical cycle operates.
Procedure for modifying parameters of validated cycles.
Procedure for creating customized cycles by copying existing ones.
Procedure for modifying parameters of customized cycles.
Troubleshooting for the Emergency Stop alarm.
Troubleshooting for load door locking system malfunctions.
Troubleshooting for unload door locking system malfunctions.
Troubleshooting for load door unlocking during a cycle.
Troubleshooting for unload door unlocking during a cycle.
Troubleshooting for spray arms that are not moving.
Troubleshooting for recirculation system malfunctions.
Troubleshooting for motor overload trips.
Troubleshooting for sump draining or recycling malfunctions.
Troubleshooting for defective water recirculation pressure transmitters.
Troubleshooting for water recycling malfunctions.
Troubleshooting for high water recirculation temperatures.
Troubleshooting for water recirculation taking too long to heat.
Troubleshooting for defective water recirculation RTD.
Troubleshooting for high temperature in Reservoir #1.
Troubleshooting for defective Reservoir #1 RTD.
Troubleshooting for reservoir overflow conditions.
Troubleshooting for Reservoir #1 not filling with hot water.
Troubleshooting for Reservoir #1 not filling with pure water.
Troubleshooting for Reservoir #2 not filling with hot water.
Troubleshooting for Reservoir #2 not filling with cold water.
Troubleshooting for Reservoir #3 not filling with hot water.
Troubleshooting for defective level sensors in Reservoir #1.
Troubleshooting for defective level sensors in Reservoir #2.
Troubleshooting for defective level sensors in Reservoir #3.
Troubleshooting for Reservoir #1 draining or transfer malfunctions.
Troubleshooting for Reservoir #2 draining or transfer malfunctions.
Troubleshooting for Reservoir #3 draining or transfer malfunctions.
Troubleshooting for abnormal chamber pressure.
Troubleshooting communication failures with the dosing system.
Troubleshooting for low level of Chemical #1.
Troubleshooting for low level of Chemical #2.
Troubleshooting for low level of Chemical #3.
Troubleshooting for low level of Chemical #4.
Troubleshooting for low level of Chemical #5.
Troubleshooting for absence of compressed air.
Troubleshooting for Reservoir #1 taking too long to heat.
Troubleshooting for defective water recirculation pressure switch.
Troubleshooting for PV chemical injection out of range for Pump #1.
Troubleshooting for PV chemical injection out of range for Pump #2.
Troubleshooting for PV chemical injection out of range for Pump #3.
Troubleshooting for PV thermal temperature out of range.
Troubleshooting for tripped over temperature switches.
Troubleshooting for outdated dosing system software.
Troubleshooting for analog sensor calibrations reset to default.
Troubleshooting for cycle parameters reset to factory defaults.
Troubleshooting temperature not reached in Reservoir #1 during DECONTAM.
Troubleshooting for improper chamber draining.
Troubleshooting chemical leaks from the dosing system.
Troubleshooting blank red screen error messages.
Troubleshooting issues with the door failing to open.
Troubleshooting door obstructions.
Troubleshooting doors that do not open completely.
Troubleshooting doors opening or closing too quickly.
Troubleshooting doors opening/closing slowly or vibrating.
Troubleshooting foam in chamber or reservoirs.
Troubleshooting floor tilting system issues.
Troubleshooting incomplete drying of loads.
Troubleshooting water flow issues in traveler spray arms.