282
window —— Configure the error symbol-period event detection interval. The
range is from 10 to 600, in terms of 100 ms intervals. The default value is 10.
notify —— Enable/Disable the event notification. By default, it is enabled.
threshold | window | notify —— The parameter that you want to return to the
default configuration.
Command Mode
Interface Configuration Mode (interface gigabitEthernet / interface range
gigabitEthernet)
Privilege Requirement
Only Admin and Operator level users have access to these commands.
Example
For error symbol-period event, configure the error threshold as 5 and the event
detection interval as 3 seconds on Gigabit Ethernet port 1/0/2:
T2600G-28TS(config)# interface gigabitEthernet 1/0/2
T2600G-28TS(config-if)# ethernet-oam link-monitor symbol-period
threshold 5 window 30
35.4 ethernet-oam link-monitor frame
Description
The ethernet-oam link-monitor frame command is used to configure the
parameters about one of the link events, error frame event. To return to the
default configurations, please use no ethernet-oam link-monitor frame
command.
Syntax
ethernet-oam link-monitor frame { [threshold threshold ] [ window window ]
[notify { disable | enable } ] }
no ethernet-oam link-monitor frame { threshold | window | notify }
Parameter
threshold —— Configure the error threshold for generating error frame event.
The range is from 1 to 4294967295 and the default value is 1.
window —— Configure the error symbol-period event detection interval. The
range is from 10 to 600, in terms of 100 ms intervals. The default value is 10.