354
f-event —— Fall Event, which is the index of the corresponding event which will
be triggered if the sampled value is lower than the
Falling Threshold. It ranges
from 1 to 12.
a-type —— Alarm Type, with rise, fall and all options. Rise indicates that the
alarm event will be triggered when the sampled value exceeds the
Rising
Threshold
, fall indicates that the alarm event will be triggered when the sampled
value is under the
Falling Threshold, and all indicates that the alarm event will be
triggered either the sampled value exceeds the
Rising Threshold or is under the
Falling Threshold. By default, the Alarm Type is all.
owner-name —— The owner of the entry, ranging from 1 to 16 characters. By
default, it is monitor.
interval —— The alarm interval time, ranging from 10 to 3600 in seconds. By
default, it is 1800.
Command Mode
Global Configuration Mode
Privilege Requirement
Only Admin level users have access to these commands.
Example
Configure rmon alarm entries 1-3 binding with statistics entry 2, the owners as
owner1 and the alarm intervals as 100 seconds:
T2600G-28TS(config)#rmon alarm 1-3 stats-index 2 owner owner1 interval
100
39.15 rmon statistics
Description
The rmon statistics command is used to configure the entries of SNMP-RMON
statistics. To delete the corresponding entry, please use no rmon statistics
command. The maximum supported entries are 1000.
Syntax
rmon statistics index interface gigabitEthernet port [ owner owner-name]
[ status { underCreation | valid }]
no rmon statistics index