167
Smart Camera / Vision-Sensor / 1D-/2D-Code-Scanner / OCR Reader
Property
Output Hold
Time
Output hold time specifies the duration of the output signal. Output signal
duration can be set within a range of 0 to 10,000 ms. Note: With an output
hold time of 0 (default value), the output retains its status until a subsequent
calculation causes its status to change.
Event 1 to 4
Delay
Output signal delay can have a value within a range of 0 to 10,000 ms or
pulses (in the case of a rotary encoder input). The output must be linked to
the corresponding event delay to this end. Up to 4 different delays can be
selected, which can be linked as often as desired to corresponding outputs.
Sequence in Trigger mode and Trigger Delay/Event Delay/Output Holdtime
Output Hold Time = 20
Event 1 Delay = 50
Capture Image
Image evaluation
Calculation results
Output
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440
Time [ms]
Trigger Delay = 20
Trigger
Image 1 Image 2
Trigger Delay
Trigger Delay
Output
Hold Time
Event Delay
Event Delay
Output
Hold Time
Output-Capture
Output-Process