20-4
IM DLM4038-02EN
Code Message Chapter or Section
651 Accessing file.
Abort or wait until it is completed, and execute again.
—
652 Printing.
Abort or wait until it is completed, and execute again.
—
653 Processing action-on-trigger.
Abort or wait until it is completed, and execute again.
2.22
654 Processing zoom search.
Abort or wait until it is completed, and execute again.
Chapter 11
655 Processing auto scroll.
Abort or wait until it is completed, and execute again.
10.1
656 Processing history search.
Abort or wait until it is completed, and execute again.
Chapter 15
657 Processing history replay.
Abort or wait until it is completed, and execute again.
Chapter 15
658 Processing statistical measurement.
Abort or wait until it is completed, and execute again.
Chapter 9
659 Analyzing serial bus data.
Abort or wait until it is completed, and execute again.
Chapter 12
660 Zone edit in process. Terminate editing. Chapter 2
661 Processing self test.
Wait until it is completed.
—
662 Acquisition in process in N Single trigger mode.
Press Start/Stop key or wait until the process is completed.
Chapter 2
663 Retrievable settings does not exist. —
664 Failed to execute statistical measurement.
Waveform data may not exist.
In Cycle statistic mode, improper setting may result in failure to recognize the cycle.
Chapter 9
665 Search target data does not exist.
Execute search after analysis is completed.
—
666 Improper action setting. The saved data type is either Waveform group or Analysis group.
This can be assigned from File menu.
Chapter 17
667 Retrievable data not found. —
668 Failed to update firmware.
Either the data file could be inappropriate or damaged.
—
669 Sending E-Mail.
Wait until it is completed.
—
670 The corresponding field was not found. —
671 Cannot be executed when the current probe setting is 100A:1V. Change the probe setting on the
channel menu or the Power Analysis Setup menu.
Chapter 1
672 Auto Deskew was canceled because input signals were not detected.
Check whether current or differential probe offset adjustments have been executed properly.
—
673 Processing math on history.
Abort or wait until it is completed, and execute again.
Chapter 15
674 Cannnot store because the data is locked.
Release the lock through Store Detail.
Chapter 17
675 Serial bus automatic setting is in progress. Please wait. Chapter 12
677 Cannot execute the user defined math function during roll mode. After acquisition stop, it will be
executed.
3.8
*
678 Cannot execute the search function during roll mode. —
679 The data length that is necessary for FFT is short.
Please make Time/div late.
Chapter 1
680 The data length that is necessary for the user defined math function is short. Please lower the
order of the MEAN operator or change setting of Filter1(Filter2).
Chapter 6
681 The data length that is necessary for the harmonics analysis function is short. —
682 The decode cannot be displayed, because the threshold level is not appropriate. —
683 Cannot execute the math function, because the display of source is OFF. Chapter 6
684 LOGIC input cannot be loaded into Ref. Chapter 17
685 Cannot load into Ref with maximum record length. —
686 Cannot execute during roll mode.
Stop and execute again.
3.8
*
687 It connects with PC Application. —
688 Cannot execute on current record length. —
* Getting Started Guide, IM DLM4038-03EN
20.1 Messages and Corrective Actions