EasyManua.ls Logo

YOKOGAWA ScopeCorder DL950 - Triggering on A Delay B (Enhanced)

YOKOGAWA ScopeCorder DL950
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-13
IM DL950-02EN
4.9 Triggering on an A Delay B Trigger (Enhanced)
This section explains the following settings for triggering on an A Delay B trigger:
Applicable in Scope Mode
Trigger source
State condition
State condition achievement condition
Delay time
Trigger conditions (trigger level, hysteresis)
► “A Delay B Trigger (Enhanced)” in the Features Guide
Trigger Menu
1.
On the waveform screen’s MENU, tap TRIGGER > MENU, or press TRIG.MENU. A trigger
menu appears.
Select Enhanced.
Set Type to A Delay B.
See “Setting the State and
Trigger Conditions.”
Set the trigger position, trigger delay, and hold-off
► sec. 4.2
Set the trigger mode. ► sec. 4.1