Figure 24 shows the timing diagram when a new indication appears after the first one
has reset but before tRestart has elapsed.
IEC01000241_2_en.vsd
Activating
signal 2
LED 2
Manual
reset
Activating
signal 1
Automatic
reset
LED 1
Disturbance
tRestart
IEC01000241 V2 EN
Figure 24: Operating sequence 6 (LatchedReset-S), two indications within
same disturbance but with reset of activating signal between
Figure 25 shows the timing diagram for manual reset.