EasyManua.ls Logo

Anritsu MS2830A - MADJMOD;MADJMOD?

Anritsu MS2830A
1452 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter
Native Device Message Details
4-139
4
Native Device Message Details
MADJMOD/MADJMOD?
ACP Reference
Function
This command sets the reference of the relative level display for ACP
measurement
Command
MADJMOD method
MADJMOD num
Query
MADJMOD?
Response
method
num
Parameter
method
Reference method for the relative level display
for ACP measurement
MOD
Uses the integral power on the entire screen as a
reference (Span Total method).
TOTAL
Same as MOD.
INBAND
Uses the total value of all carrier power as a
reference (Carrier Total method).
BOTHSIDE
The carrier power of the largest carrier number
is used as a reference for the upper offset, while
the carrier power of the smallest carrier number
is used as reference (Both Sides of Carriers
method).
num
Carrier number used as a reference when the
reference of the relative level display for
Adjacent Channel Power measurement is set to
Carrier.
Range 1 to Carrier Number (cf.
ADJCARRIERNUM
)
Resolution 1
Suffix Code None
Example of Use
To set the ACP measurement method to Inband.
MADJMOD INBAND
MADJMOD?
> INBAND