2.13 Spectrum Emission Mask
2-661
2
SCPI Device Message Details
:CALCulate:SEMask:OFFSet[1]:LIST:STARt:ABSolute[1]|2
<ampl_1>[,<ampl_2>[,<ampl_3>[,<ampl_4>[,<ampl_5>[,<ampl_6>[,<ampl_7
>[,<ampl_8>[,<ampl_9>[,<ampl_10>[,<ampl_11>[,<ampl_12>]]]]]]]]]]]
Spectrum Emission Mask Offset Start Frequency Absolute Limit Level
Function
This command sets the absolute level upper limit of the offset start
frequency for Spectrum Emission Mask measurement.
Command
:CALCulate:SEMask:OFFSet[1]:LIST:STARt:ABSolute[1]|2
<ampl_n>
Parameter
<ampl_n>
Absolute level upper limit of Offset-n start
frequency
Range 200 to +50 dBm
Resolution 0.01 dB
Suffix code DBM,DM
dBm is set when omitted.
Details
ABSolute1 sets the absolute level upper limit 1, and ABSolute2 sets the
absolute level upper limit 2.
Example of Use
To set the absolute level upper limit 2 of the start frequency of the offset.
CALC:SEM:OFFS:LIST:STAR:ABS2
0,-2,-2,0,0,-10,0,-2,-2,0,0,-10
Related command
This command has the same function as the following command.
[:SENSe]:SEMask:OFFSet[1]:LIST:STARt:ABSolute[1]|2