2.14 Spurious Emission Measurement Function
2-773
2
SCPI Device Message Details
:CALCulate:SPURious[:RANGe][:LIST]:LIMit:ABSolute[:UPPer]:DATA[:STARt]
?
Spurious Emission Limit Start Level Query
Function
This command queries the absolute level limit of the start frequency in
each segment for the Spurious Emission measurement.
Query
:CALCulate:SPURious[:RANGe][:LIST]:LIMit:ABSolute[:UPPer
]:DATA[:STARt]?
Response
<ampl_n>
Parameter
<ampl_n>
Absolute level limit of start frequency of
Segment n
Range 200 dBm to 50 dBm
Resolution 0.01 dB
Suffix code None. Value is returned in dBm units.
Example of Use
To query the absolute level limit of the start frequency in each segment.
CALC:SPUR:LIM:ABS:DATA?
>
13.00,13.00,13.00,13.00,13.00,13.00,-10.00,-10.00,
13.00,13.00,13.00,13.00,13.00,13.00,-10.00,-10.00,
13.00,13.00,13.00,13.00