Chapter 2 SCPI Device Message Details
2-168
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:POWer:NEXT
Next Power Peak Search
Function
This command searches for the next largest peak power in the zone
width compared to the total power of the zone width of the active marker
in the measurement band and moves the active marker.
Command
:CALCulate:MARKer[n]:MAXimum:POWer:NEXT
Parameter
<n>
Marker No.
1
Specifies marker 1
2
Specifies marker 2
3
Specifies marker 3
4
Specifies marker 4
5
Specifies marker 5
6
Specifies marker 6
7
Specifies marker 7
8
Specifies marker 8
9
Specifies marker 9
10
Specifies marker 10
When omitted:
Specifies marker 1
Details
This function is not available under the following condition:
When in Time Domain
When Scale Mode is Linear scale.
When Active Trace is Blank.
When Spurious Emission measurement is enabled, and also Displayed
Segment Mode is set to Auto.
When Spectrum Emission Mask measurement is enabled.
Example of Use
To move marker 1 to the position with the next largest peak power
CALC:MARK:MAX:POW:NEXT
Related command
This command has the same function as the following command.
:CALCulate:ACPower:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:
POWer:NEXT
:CALCulate:SPURious:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum
:POWer:NEXT