2
SCPI Device Message Details
[:SENSe]:ACPower:ADVanced:OFFSet:LIST[:FREQuency]
<freq>,<freq>,<freq>,<freq>,<freq>,<freq>,<freq>,<freq>
Adjacent Channel Power Offset Frequency
Function
This command sets the offset channel frequency for Adjacent Channel
Power measurement.
Command
[:SENSe]:ACPower:ADVanced:OFFSet:LIST[:FREQuency]
<freq_1>,<freq_2>,<freq_3>,<freq_4>,<freq_5>,<freq_6>,<f
req_7>,<freq_8>
Parameter
<freq_n>
Offset channel n offset frequency
Range –125 to 125 MHz
Resolution 1 Hz
Suffix code HZ, KHZ, KZ, MHZ, MZ, GHZ, GZ
Hz is used when omitted.
Default
freq_1
5 MHz
freq_2
10 MHz
freq_3
15 MHz
freq_4
15 MHz
freq_5
15 MHz
freq_6
15 MHz
freq_7
15 MHz
freq_8
15 MHz
Details
This function can be set when the following trace is active.
•
Spectrum
To query the measurement results after executing this command, use the
*WAI command to control synchronization.
Example of Use
To set offset channel offset frequency and query results.
ACP:ADV:OFFS:LIST
30KHZ,50KHZ,70KHZ,90KHZ,110KHZ,130KHZ,150KHZ,170KHZ
*WAI
FETC:ACP?