2.4 Marker
2-139
2
SCPI Device Message Details
:CALCulate:MARKer:RESult INTegration|DENSity|PEAK
Marker Result
Function
This command sets the type of the marker display value.
Command
:CALCulate:MARKer:RESult <mode>
Parameter
<mode>
Type of Marker display value
INTegration
Total Power in the zone band
DENSity
Power per 1 Hz in the zone band
PEAK
Peak power in the zone
Details
Integration and Density cannot be set when Scale Mode is Lin.
Also, Integration cannot be set when Time Domain mode is selected.
Automatic setting of the peaking bias value cannot be used during
Spurious measurement and when Displayed Segment Mode is Auto.
Not available during Spectrum Emission Mask measurement.
The type of Marker display value is set to the peak power in the zone
when the N dB Bandwidth measurement function is set to On.
Example of Use
To set the marker display value to the total power in the zone band.
CALC:MARK:RES INT
:CALCulate:MARKer:RESult?
Marker Result Query
Function
This command queries the type of the marker display value.
Query
:CALCulate:MARKer:RESult?
Response
<mode>
Parameter
<mode>
Type of Marker value
INT
Total power in the zone band
DENS
Power per 1 Hz in the zone band
PEAK
Peak power in the zone
Example of Use
To query the type of the marker display value.
CALC:MARK:RES?
> INT