2.14 Spurious Emission Measurement Function
2-809
2
SCPI Device Message Details
:CALCulate:SPURious:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum
Spurious Emission Peak Search
Function
This command searches for the maximum level point of active trace and
moves the marker point to it.
Refer to
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum.
Related Command
This command has the same function as the following commands.
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum
:CALCulate:ACPower:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum
:CALCulate:CHPower:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum
:CALCulate:OBWidth:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum
:CALCulate:BPOWer|:TXPower:MARKer[1]|2|3|4|5|6|7|8|9|10:
MAXimum
:CALCulate:SPURious:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:NEXT
Spurious Emission Next Peak Search
Function
This command searches for the feature point of the active trace and
moves the marker point to the peak point below the level of the active
marker.
Refer to
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:NEXT.
Related Command
This command has the same function as the following commands.
:CALCulate:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:NEXT
:CALCulate:ACPower:MARKer[1]|2|3|4|5|6|7|8|9|10:MAXimum:
NEXT