<Concerning operations when Auto (0) has been selected as the Follower:
Mode setting>
In order to define the adjoining device of the generator, the connection location
of the generator is checked by reading the physical address of the EDID
connected to the generator. An error results if it has been determined that this
physical address cannot be obtained (because the EDID of the connection
destination cannot be read or because the EDID is not the HDMI EDID, for
instance). In a case like this, EXECUTE must be selected again.
In order to define the adjoining device of the generator, a CED command is
sent from the generator. An error results if the response to this command is
illegal and the generator cannot define the adjoining device. In a case like this,
EXECUTE must be selected again.
If, based on the response to the command sent, it has been determined that
two or more devices adjoin the generator (because their physical addresses
are identical, for instance), the adjoining device is identified with the lower or
lowest logical address is identified to be the adjoining device.
<Concerning the CEC response commands>
A response is given to the following reception commands while the ARC pattern is
selected.
When Auto (0) has been selected as the Follower: Mode setting
Reception command Response command
Command Send source Command
Send
destination
Give Physical
Address
All sources Report Physical Address
* Only when it has been
possible to obtain the
physical address from the
EDID
* The Device Type of the
address set by VG Logical
Address is used as the
Device Type among the
parameters. However,
other Device types are
used for the addresses
listed below.
Ch: Reserved
Dh: Reserved
Eh: Video Processor
Fh: No response
Broadcasts
Request ARC
Initiation
Adjoining
device
Initiate ARC
Adjoining
device
Request ARC
Termination
Adjoining
device
Terminate ARC
Adjoining
device
When Manual (1) has been selected as the Follower: Mode setting
Reception command Response command
Command Send source Command
Send
destination
Request ARC
Initiation
Follower:
LogicalAddr
setting
Initiate ARC
Follower:
LogicalAddr
setting
Request ARC
Termination
Follower:
LogicalAddr
setting
Terminate ARC
Follower:
LogicalAddr
setting
CAUTION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ASTRO VG Series and is the answer not in the manual?

ASTRO VG Series Specifications

General IconGeneral
BrandASTRO
ModelVG Series
CategoryPortable Generator
LanguageEnglish

Related product manuals