Chapter 4 INTERFACE SETTINGS
253
4.13.4 V-by-One HS Control
The VM-1825 makes it possible to control the V-by-One HS control signals (HTPDN and LOCKN).
<Operating procedure>
Select V-by-One HS Control using
MENU
or
INC
DEC
, and then press
SET
.
<Control parameters>
These parameters are used for channel 1 and channel 2 control.
-
Through
The signals from the receiver are passed straight through.
L
Forced Low
The signal is forcibly set to low.
(1)
H
Forced High
The signal is forcibly set to high.
(2) The current statuses of channel 1 and channel 2 are indicated here.
The statuses are displayed in solid white lettering against a black background if the signals have been
forcibly set to low or high.
(1) (2)