392
0.25-/0.125-dot scrolling settings
For details on the action selection procedure, refer to “2.1.4 Selecting the actions.”
(1)
Select Program Edit using
MENU
or
INC
DEC
, and then press
SET
.
(2)
Select Action (PAT) using
or
INC
DEC
, and then press
SET
.
(3) Select “0.25dot Scroll” or “0.125dot Scroll”
using
or
INC
DEC
, and then press
SET
.
<Selecting the items>
Select the items using
or
INC
DEC
,
and then press
SET
.
(4)
<Setting the parameters>
Select the parameters using
or
INC
DEC
, and then press
SET
.
Alternatively:
Select the parameters using the number keys
(
0/STATUS
to
9/F
), and then press
SET
.
For further details, refer to <Table of 0.25-/0.125-dot
scrolling setting items>.
<Table of 0.25-dot and 0.125-dot scroll setting items>
On or Off for 0.25-/0.125-dot scrolling is set here.
0
OFF
0.25-/0.125-dot scrolling is set to Off.
(1)
OFF/ON (0/1)
1
ON
0.25-/0.125-dot scrolling is set to On.
The direction of 0.25-/0.125-dot scrolling is set here.
0
Left
Scrolling moves to the left.
(2)
Direction (0/1)
1
Right
Scrolling moves to the right.
(3)
Step
The amount of movement per 1 V is set here.
0.25-dot scroll setting range: 0.00 dot to 254.75 dots (0.25 dot Step)
0.125-dot scroll setting range: 0.000 dot to 254.750 dot (0.125 dot Step)
(4)
V-offset
The value of V-offset is set here.
Setting range: 0.0 to 100.0% (0.1% Step)