EasyManua.ls Logo

Bosch EPS 118 - Spare Parts and Decommissioning

Bosch EPS 118
694 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 689 989 300 2020-03-24| Robert Bosch GmbH
Maintenance | EPS 118 | 87 en
Assembly
1. Slide the new filter element (Fig. 47, item 5) onto
the deflector (Fig. 47, item 6).
2. Secure the deflector plate (Fig. 47, item 4).
3. Before installing the filter assembly, check if the
O-ring (Fig. 47, item 7) is present and correctly
installed on the condensate vessel.
4. Insert the filter assembly (Fig. 47, item 3) into the
condensate vessel and turn it by 45° to secure it.
5. Before installing the condensate vessel, check if
the O-ring (Fig. 47, item 8) is present and correctly
installed on the deflector.
i On the condensate vessel, there are two lines
(Fig. 48, item 1,2) to the left and right of the
lock. While the condensate vessel is inserted
into the maintenance unit, one of the lines must
align with the indentation (Fig. 48, item 3) on
the maintenance unit. Then, turn the condensate
vessel in the direction of the indentation until
the lock engages audibly.
458900-27_Pal
2
1
3
Fig. 48: Condensate vessel installation position
6. Secure the condensate vessel (Fig. 47, item 1) on
the maintenance unit (Fig. 47, item 9).
7. Connect the compressed-air line to the mainte-
nance unit.
8. Switch on the compressed air.
9. Check for leakage. In case of leakage, check instal-
lation position of the condensate vessel.
10. Check if the condensate hose is still properly run
into the collecting container.
8.3 Spare and wearing parts
Designation Order number
Maintenance package with:
R 100 x strainer
<)
R 10 x o-ring 7.66 x 1.78
<)
R 1 x air filter for maintenance unit
<)
R 1 x test oil filter
<)
1 687 010 576
Degassing adapter
<)
1683457129
Sealing plug for leak check
<)
1683080012
Connection adapter
<)
1681032120
High-pressure hose assembly
<)
1680712389
1)
Hose assembly (return)
<)
1684462570
Bosch Piezo CRI hose assembly (return)
<)
1684462569
Adapter cable for Bosch CRI/piezo CRI
<)
1684463952
Adapter cable for CRIN
<)
1684463953
Bosch CRI hose fitting with O-ring
<)
1681334034
Bosch CRI 2.5 hose fitting with O-ring
<)
1681032119
Bosch CRIN hose fitting
<)
1683386192
CRIN adapter with check valve for Bosch in-
jectors
<)
1683350904
Inlet connector
<)
1 683 386 166
12 x O-rings 9.5 x 2 for inlet connector
<)
1 680 210 143
Adapter M12 — M14
<)
1681321362
O-rings for injection chamber
R 20 x O-rings 7mm
<)
R 20 x O-rings 9mm
<)
1687010519
O-rings for injection chamber
R 20 x O-rings 60.05mm
<)
R 20 x O-rings 69.57mm
<)
1687010520
Clamping bush (17mm)
<)
1681091184
Clamping bush (19mm)
<)
1681091185
Clamping bush (21mm)
<)
1681091186
WLAN-USB-Adapter 1 687 010 561
High-pressure pump control valve
<)
1)
<)
Wearing parts
1)
Customer service performs maintenance and exchanges.
i Parts that are subject to wear from use or other na-
tural causes of wear or must be exchanged during
maintenance are not covered by the guarantee.

Table of Contents

Related product manuals