108/188 Installation
Bosch Rexroth AG, MIT: ActiveMover, 3 842 564 874/2021-04
7.6.18 Emergency safety circuit
DANGER
There is a risk of serious injury or death if the specifi cations for emergency stop
safety circuits are not observed!
The emergency stop safety circuits must meet the following specifi cations:
Stop category 1 according to DIN EN 60204-1
The system must be surrounded entirely by a separating safety device in
accordance with DIN ISO EN 14120.
Access doors must be electrically locked and have guard locking.
Opening of the access door must be prevented for at least 5 seconds after the
motors of the curve and section modules have shut down.
The required performance level in accordance with DIN EN ISO 13849 must
be PL
r
= d.
It must not be possible to start up the ActiveMover with the safety door open!
Connect the emergency stop safety circuits according to the circuit diagram.