186/188 Appendix
Bosch Rexroth AG, MIT: ActiveMover, 3 842 564 874/2021-04
Calibration set 3 842 559 456
• Weight 2.14 kg
16.4 IR ID system
Laser class 1 according to DIN EN 60825-1:2008
Other standards and directives IEC EN 60825-1:2007
IEC 62471 (2006)
CIE S009 (2002)
Directive 2006/25/EC
16.5 Ambient conditions
ActiveMover is designed for stationary use in indoor areas.
• Ground The ground must be level and designed for the
mechanical load of the ActiveMover.
• Permitted capacity
of the ground: 1000 kg/m
2
• Ambient temperatures and relative humidity
– Operation Temperature 5 … 55 °C
Humidity 5 … 85 %, non-condensing
– Storage Temperature -25 … 55 °C
Humidity 5 … 95 %, non-condensing
– Transport Temperature -25 … 70 °C
Humidity max. 95 % at 40 °C
17 Appendix
17.1 Trademark information
• EtherNET/IP™ is a trademark of ODVA Inc.
• PROFINET® is a registered trademark of
PROFIBUS Nutzerorginisation e.V.
• Ethernet POWERLINK is a trademark of
B&R Industrial Automation GmbH
• EtherCAT® is a registered trademark of
Beckhoff Automation GmbH & Co. KG