120/188 Maintenance and repair
Bosch Rexroth AG, MIT: ActiveMover, 3 842 564 874/2021-04
10 Maintenance and repair
DANGER
Serious injury or death from electric shock!
In areas that are marked with this danger symbol, there is a danger of severe
injuries and burns caused by potentially fatal fl ashover and electrical shock.
Observe all the requirements of NFPA 79 (NA) and DIN EN 60204-1 (EU) for
safe working on electrical installations, as well as all national and international
regulations that are applicable at the place of use.
Wear personal protective equipment that is appropriate for the place of use and
use suitable tools.
Serious injury or death due to energy stored after switch-off!
After the power supply of motors for section and curve modules has been
shut down, a risk of serious injuries and burns still exists due to energy
accumulated in the capacitors that can even lead to death.
After shutting down the power supply, access needs to be blocked by means of
separately locked protective equipment with guard locking so that the energy
present in the capacitors can dissipate.
WARNING
High electrical voltage!
Risk of severe injury or death from electric shock.
Disconnect the relevant system component before performing any maintenance
or repair work.
Secure the system against being unintentionally switched on again.
CAUTION
Sudden movements, falling objects
Risk of injury caused by sudden movements and falling objects.
Only carry out work on the ActiveMover when the system is switched off and in
safe condition.
Secure the system against being unintentionally switched on again.
Hot surfaces up to 90 °C of the section/curve module during operation!
Hot surfaces up to 70 °C of the electronic components during operation!
Risk of burns from touching hot surfaces above 65 °C.
Install appropriate guards.
Let the unit cool down for at least 30 minutes before performing maintenance
and/or repair work.