EasyManua.ls Logo

Bosch Rexroth ActiveMover - Repair; Required Mechanical Tools; Required Electrical Tools

Bosch Rexroth ActiveMover
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and repair 129/188
3 842 564 874/2021-04, MIT: ActiveMover, Bosch Rexroth AG
10.4 Repair
10.4.1 Required mechanical tools
Hex wrench SW13
Hex socket wrenches SW3, SW4, SW5, SW6
Posidriv screwdriver PZ2
Caliper, 500 mm
Rubber mallet
Drift punch
10.4.2 Required electrical tools
Various screwdrivers with insulating handles
Side cutter with insulating handles
Stripping tool with insulating handles
Multimeter
CAUTION
Strong magnetic fi eld!
There is a risk of injury from strong magnetic fi elds in areas that are marked
with this danger symbol.
If workpiece pallets are not mounted on the linear motor system, they have
a strong magnetic fi eld!
- The strong magnetic fi eld of the workpiece pallets may be harmful to
people with cardiac pacemakers and other medical implants.
- The magnetic fi eld of the ActiveMover linear motor system can cause magnetic
materials to move, leading to a risk of projectiles or crushing/shearing.
- Electronic equipment and magnetic media can be infl uenced by the magnetic fi eld.
Persons with cardiac pacemakers or other medical implants must maintain
a minimum distance of 30 cm from the implant position to the workpiece pallet.
Persons with cardiac pacemakers or other medical implants are not suitable for
maintenance or service works at the system.
Keep metal objects at a distance from the workpiece pallets and the
section/curve modules.
When the workpiece pallets are not assembled, the corresponding protective
plates must be attached. Assembly instructions see page 84.
Also observe the safety instructions in chapter "General safety instructions for
magnets" on page 33.

Table of Contents

Related product manuals