184/188 Technical data
Bosch Rexroth AG, MIT: ActiveMover, 3 842 564 874/2021-04
16 Technical data
16.1 Mechanical data
Max. speed Standard section straight: 4 m/s
In the curve area: approx. 2.5 m/s at 1 kg
Acceleration
Load 1 kg Standard section straight: 40 m/s²
Curve: 20 m/s²
Load 10 kg Standard section straight: 10 m/s²
Curve: 5 m/s²
Load
WT with 3 magnets 10 kg
WT with 2 magnets up to approx. 2 kg
16.2 Electrical data
Operating voltage
Europe 400 V AC (3-phase 230 V AC) + N + PE, 50 Hz
America 208 V AC (3-phase 120 V AC) + N + PE, 60 Hz
Short-circuit protection 1.4 kA
Max. current consumption 55 A
Power consumption 10 W/section, 150 to 275 W/WT
(depending on the application)
Servo update rate 800 µs (typ.)
Power consumption
Gateway board 6 W/section/curve module
Power output
Power supply max. 1500 W
Control voltage 24 V DC (digital)
28 V DC (motor)
Current at full load 30 A
UPS voltage 24 V DC 50/60 Hz
Nominal current strength 15 A
16.3 Dimensions and weight
Base frame 3 842 559 450 (without leveling feet)
Length x width x height 900 x 500 x 603 mm
Weight 135 kg
Base frame 3 842 559 451 (without leveling feet)
Length x width x height 383.25 x 500 x 603 mm
Weight 62 kg
Section module connection kit 3 842 559 452
Weight 17 kg
Curve module connection kit 3 842 559 453
Weight 17 kg