Commissioning 115/188
3 842 564 874/2021-04, MIT: ActiveMover, Bosch Rexroth AG
• Make sure that all electrical connections are either used or covered. Make sure
that all bolted connections and plug-in connections are properly seated, especially
protective conductor connections. All relevant protective covers must be fi tted.
Notice: The system integrator must ensure that the ActiveMover system is
connected to the equipment grounding conductor of the customer system!
• Removing or lifting protective equipment and/or operation without safeguards are
not permitted on the ActiveMover.
• Observe DIN EN ISO 13857 when you remove or replace protective equipment
and/or bypass safety equipment.
• Only start up the product if all safety equipment has been installed in the system
and is functional.
• Only start up a product that has been completely installed.
• Check the complete and correct assembly again (see chapter 7.5).
• Check the correct and complete electrical connection again (see chapter 7.6).
• Carry out the measurements before starting up the system for the fi rst time
(see chapter 8.1)