Maintenance and repair 145/188
3 842 564 874/2021-04, MIT: ActiveMover, Bosch Rexroth AG
Fig. 103:
557 186-92
4
!
SW3
SW3
13x
5
6
!
10x
M
D
=2 Nm
Plastic
Replacing the printed circuit board (coil driver) (section module)
4. Remove the printed
circuit board
(1 plastic screw +
13 metal screws).
5. Remove the printed
circuit board and pull off
the 5 thermistor plugs.
6. Check that all 10 fuses
(15 A) are present on
the new printed circuit
board.
Install the new printed
circuit board in reverse
order.
Please note:
During installation of the
new printed circuit board,
there must not be any lines
behind the circuit board.
This could lead to short
circuits.