90/188 Installation
Bosch Rexroth AG, MIT: ActiveMover, 3 842 564 874/2021-04
NOTICE
When working at electrical systems, observe the 5 safety rules!
De-energize.
Secure against reactivation.
Ensure absence of voltage on all poles.
Ground and short-circuit.
Cover or block off any adjacent live parts.
• Choose control and sensor elements in accordance with EN ISO 13849. Factor in
the load being transported and the transport speed.
• Electrical connection must only be carried out by qualifi ed personnel.
• Comply with DIN EN 60204-1 or the corresponding regulations in the country
of use.
• Observe the available supply voltage!
• Take account of the electrical power requirement shown on the nameplate,
see fi g. 27 on page 48.
• Take account of the circuit diagram included in the scope of delivery.