Description Symbol Unit REH0800
Oil resistance EN 60811-2-1 and EN 50363-10-2
Flammability
EN 60332-1-2; UL 758, Sec. 40, Cable Flame Test
Sec. 1061 according to UL 1581 and CSA C22.2 No.
210-05, Sec. 8.8.2
Latest amendment: 2019-06-17
1) According to EN 50363-10-2
2) 3) 4) Flexible cable track parameters: Maximum values only apply
individually
5) UL file number according to cable marking
Tab. 5-19: REH - Technical data
The hybrid cable contains both power lines and control lines.
Route hybrid cables in accordance with EN 61800‑5‑1 and
EN 61800‑5‑2, protected against external damage. Select the
types of protective measures according to the respective
application.
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
115/407
Technical data of the components
R911335703_Edition 04 Bosch Rexroth AG