X141, without safety technology
Devices without safety technology can be operated within a safety
zone, because the signals are transmitted to the next safety zone
node via X103.1 and X103.2. The RBS0023 safety zone
connector is not required.
There is no reaction to the signals of safety technology.
View Connecti
on
Signal name Function
Female connector M12 (12‑pin,
D‑coded)
1 n. c. -
2 n. c. -
3 Zone_Br X141.3 has to be accordingly controlled for the desired
function:
● "Release brake":
Short circuit to X141.9
(input voltage: 24 V ±20%)
4 n. c. -
5 n. c. -
6 n.c. -
7 n. c. -
8 n. c. -
9 24V_Br Internal interface only;
24 V for "release brake" function
10 n.c. -
11 - -
12 n. c. -
Ready-made connection cable RKB0033
Can be used to "release brake".
Tab. 6-31: Function, pin assignment, properties
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
177/407
Connection points
R911335703_Edition 04 Bosch Rexroth AG