Description Symbol Unit Value
Maximum concentration of corrosive gases According to degree of protection
Vibration sine: axial
acceleration at 10 … 2000 Hz
1)
- g 1
Vibration sine: radial
acceleration at 10 … 2000 Hz
1)
- g 1
With HAS10.1-001-001-NN accessories:
3
Overvoltage category - - III (according to IEC 60664-1)
1) According to EN 60068-2-6
2) Reduced performance data for drive controllers: allowed DC
bus continuous power, braking resistor continuous power, con‐
tinuous current
3) Reduced performance data for motors: performance, torque S1
and S3
Tab. 4-9: Ambient and operating conditions (KSM)
Ambient and operating conditions (KMS, KMV, KNK, KLC)
Description Symbol Unit Value
Degree of protection (IEC 60529) - - IP65
Use within scope of CSA / UL - - For use in NFPA 79 Applications only!
Temperature during storage - - See chapter 4.2.2 "Storing the components" on
page 47
Temperature during transport - - See chapter 4.2.1 "Transporting the components" on
page 47
Allowed mounting position
Definition of mounting positions: See chapter
"Mounting positions of components" on page
58
- - KMS G1, G2, G3, G4, G5
(KMS03.1B-A: reduced
performance with G2, G4, G5)
KMV, KNK, KLC Cooling types B and I: G1, G2,
G3, G4
Cooling types A and W: G1
Installation altitude h
nenn
m 1000
Ambient temperature range T
a_work
°C 0 … 40
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
53/407
General data and specifications
R911335703_Edition 04 Bosch Rexroth AG