Operation C 2
ekrPro Com
60
web guide controller EDV-No.: MD.191.01.05/1.6.x Chapter: C 2
with analog sensors Date: 23.11.2007 Page: 11/19
C 2.4.1 Automatic material set-up
1. Press the F1-key.
2. Completely cover the sensor’s scanning window with the
material to be scanned for approx. 2 seconds.
3. Completely remove the material from the sensor scanning
window (no material over the sensor).
4. Press the F2-key
This completes the material set-up for this sensor. Material set-up
has been completed when the same procedure has been carried
out for any other sensors connected to the controller.
C 2.4.2 Manual material set-up
For the reflection sensor TW 54 C5 and the line
sensor T 62 D 1 a special material setup is to be
carried out (see chapter C 2.4.4).
1. Completely cover the sensor’s scanning window with the
material to be scanned.
2. Press the F3-key.
3. Completely remove the material from the sensor scanning
window (no material over the sensor).
4. Press the F4-key
The sequence is arbitrary, i.e. the dark setting (steps 1 and 2) or
the light setting (steps 3 and 4) can be made first.