358
c HELP Mode Function and Operation Procedures
chap.7
H-59
(1) Adjustment / specification settingHELP mode
1. Functions
(1) Setting of: intermittent paper feed mode, master clump
application/release timing for master attachment, count
change when ink is absent, fine start mode ON/OFF
2. Operation procedures
Modes H-56 and H-58 are not used. For H-57, refer to H-52.
Display Item Setting
0
***
1
***
*
0
**
Setting for master clump open-
ing/closing timing for master
attachment
C mode
f
master fed out
f
B mode
*
1
**
Master fed out
f
C mode
f
B mode
**
0
*
Changing of out-of-ink count.
Display of out-of-ink count
Changing of count value
Standard (20 revolutions at speed 3)
**
1
*
Treble (60 revolutions at speed 3)
***
0
Dis/enabling of Fine Start Mode
Enabled ((activated by HELP60/opera-
tion panel settings)
***
1
Disabled (enforced deactivation)
0 0 1 0
Factory setting
- L -
****
Correction amount display
During memorization:
(1) Setting of: intermittent paper feed mode, master clump
application/release timing for master attachment, count
change when ink is absent, fine start mode ON/OFF
qAccess HELP mode H-59, and press the PRINT key.
For the basic procedure for accessing HELP modes.
wUse the [0] and [1] numeric keys to enter a 4-place binary value for
the desired correction amount. See the table below for 4-place
binary values and the corresponding correction amounts.
rPress the STOP key. The HELP mode selection display will
reappear.
a To exit the HELP mode : Turn the power switch OFF.
a To access another HELP mode : Enter the desired mode number
using the numeric keys.
ePress the [=] key. The correction amount will be memorized
in the battery PCB unit's EEPROM. During memorization, "-L-"
will be displayed.
Do not turn off the power before the "-L-" display has disappeared.
IMPORTANT
\See page 291
*1
*1:Stopgap action for failure of ink
roller motor / contact pressure mo-
tor.
Failure of these motors can be by-
passed by setting "
***1
" for
HELP59. This setting is in fact intended
for deactivating these motors in factory
tests, but it has the effect of causing
initialization of these motors to be omit-
ted at machine start-up.