System Functions 109
Fault Analysis Mode
5
There are various system faults that can be detected by the control panel. When any of these
faults are present, the
FAULT
indicator will begin to flash and the codepad will beep once every
minute. Refer to Fault Descriptions on page 64 for a more detailed description on each fault
type.
How To Determine The Type Of Fault
1.
Hold the
5
button down until two beeps are heard.
The
STAY
and
AWAY
indicators will begin to flash in unison with the
FAULT
indicator.
One or more
ZONE
indicators (1-8) will illuminate to indicate the type of fault that has
occurred.
How To Exit Fault Analysis Mode
1.
To exit fault analysis mode, press the button.
The
STAY
and
AWAY
indicators will extinguish and return you to the disarmed state.
Zone Indicator Fault Description
Low Battery
Date and Time
Sensor Watch
Horn Speaker Disconnected
Telephone Line Fault
E
2
Fault
Fuse Fail
Communications Failure
6
7
Table 42: Fault Indicators
Initiate A Modem Call
Holding the
6
button down until two beeps are heard will force the control panel to dial the
call back telephone number programmed in "LOCATION 159 - 174" on page 139 in an
attempt to connect to the installer’s remote computer.
The remote computer will be required to be running the Alarm Link Software (CC816) and
will need to be set to “Waiting For An Incoming Call". If no call back telephone number has
been programmed, holding down the
6
button will have no effect.
Reset Latching Outputs
Holding the
7
button down until two beeps are heard will reset any programmable output that
has been programmed to remain on once it has been activated.
The output will need to be programmed with a latching polarity. Refer to Output Polarity on
page 199 for further information.
Electronics Design and Manufacturing Pty Limited ISSUE130