176
Solution 862
Installation Manual
Reporting Information
This section covers features that are involved with the basic house keeping of the system. This
includes monitoring of the zones - whether they are isolated from the system or more
importantly that they are actually operating, the status of both the AC mains and DC power to
the system and codepad generated alarms activated by the user.
Zone Status – Bypass Reports
LOCATION 325 - 326
98
Location Description
325
Zone Bypass Report
326
Zone Bypass Restore Report
Table 80: Zone Status - Bypass Report Locations
A zone is bypassed when it is manually isolated. Refer to Isolating Zones on page 60 for
information on isolating zones. A "Zone Bypass" report (Contact ID Event Code 570) will be
transmitted at the end of exit time for any zone that has been manually isolated. 24-hour zones
will send a “Zone Bypass” report at the time the zone has been selected to be isolated.
A "Zone Bypass Restore" report will be transmitted when the system has been disarmed. All
bypassed zones are automatically cleared when the system has been disarmed.
The bypass code parameter is used as the expansion digit in 4+2 Formats. It has no effect on
Contact ID Format as a zone bypass will always be reported on event code 570.
If "Zone Bypass" reports are not required, program "LOCATION 325 - 326" with a zero.