220
Solution 862
Installation Manual
Consumer Options 2
LOCATION 429
2
Option Description
1
Codepad Display Extinguish After 60 Seconds
2
Single Button Arming Allowed (AWAY/STAY Mode 1 & 2)
4
Single Button Disarming Allowed (STAY Mode 1 & 2)
8
Alarm Memory Reset On Disarm
1
2
4
8
Table 130: Consumer Options 2
Codepad Display Extinguish After 60 Seconds
If this option has been selected, all indicators on the remote codepad display will extinguish if
a button is not pressed for 60 seconds. The indicators will illuminate when there is an alarm
(except a silent alarm), when a button is pressed on the codepad, when the AC mains fail
beeps, or if the entry timer has been activated.
Single Button Arming Allowed (AWAY Mode/STAY Mode 1 & 2)
If this option has been selected, the hold down functions for arming in AWAY Mode, STAY
Mode 1 and STAY Mode 2 will be functional. Refer to Hold Down Functions on page 107 for
more information.
Single Button Disarming Allowed (STAY Mode 1 & 2)
This option will only operate when Option 2 in this location has also been selected. This
option will allow hold down functions for disarming from STAY Mode 1 and STAY Mode 2.
Refer to Hold Down Functions on page 107 for more information.
Alarm Memory Reset On Disarm
This option allows the memory of alarm events to be cleared from the remote codepad when
the system has been disarmed. If this option has not been selected, the system will need to be
armed and disarmed again to clear alarm memory from the remote codepad.
ISSUE130 Electronics Design and Manufacturing Pty Limited